Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of the Korean Society of Neonatology ; : 301-309, 2011.
Article in English | WPRIM | ID: wpr-115971

ABSTRACT

PURPOSE: Point-of-care tests (POCTs) have the potential to significantly influence management of neonates. The aim of this study was to assess the clinical usefulness of the POCT chemistry analyzer in a neonatal intensive care unit (NICU). METHODS: Blood samples of neonates admitted to the NICU were tested using a POCT chemistry analyzer (Piccolo Xpress Chemistry Analyzer, Abaxis, Union City, CA, USA) and a central laboratory chemical analyzer (Chemistry analyzer 7600-110, Hitachi Ltd., Tokyo, Japan) from March to September, 2010. Correlation of 15 analytes between the POCT and the central laboratory machine was evaluated. For consistency of the POCT, three consecutive samplings were performed. Differences among the three tests were recorded. The causes of performance errors were checked through log files. RESULTS: One hundred of 112 pairs of tests for accuracy performed in 54 neonates showed a high correlation between the two machines. Twelve performance errors occurred during the 112 tests. The most common error was insufficient sample error. Eighteen triplet tests performed in 18 patients for consistency revealed a difference range of 3-10%, which was considered to be acceptable. No error occurred during the 54 tests. CONCLUSION: The POCT is capable of analyzing multiple analytes with a minimal amount of whole blood in a short time. The few performance errors noted presently are likely preventable. This POCT is concluded to be suitable for use as a simple and rapid diagnostic method in the NICU with a minimal amount of blood collected in a less invasive manner.


Subject(s)
Humans , Infant, Newborn , Intensive Care Units, Neonatal , Intensive Care, Neonatal , Point-of-Care Systems , Tokyo , Triplets
2.
Journal of the Korean Society of Neonatology ; : 387-390, 2011.
Article in English | WPRIM | ID: wpr-59450

ABSTRACT

Spontaneous neonatal esophageal perforation (EP) is a rare condition. However, iatrogenic EP due to a feeding tube is not uncommon, particularly in premature infants. Iatrogenic EP can result in serious complications, such as a pneumothorax, and can be fatal. Usually a pneumothorax develops as a result of EP. However, we experienced an EP in a patient with a pneumothorax. The EP occurred after inserting a feeding tube while the patient was suffering from a pneumothorax. Thus care is needed when inserting the feeding tube in a patient with a pneumothorax.


Subject(s)
Humans , Infant, Newborn , Complex Mixtures , Esophageal Perforation , Infant, Premature , Pneumothorax , Stress, Psychological
SELECTION OF CITATIONS
SEARCH DETAIL